UL approval file name. The contactor programme CI 6-50 is based on three frame sizes.

Danfoss Type Ci 16 Wiring Diagram - If you're looking for picture and video information related to the key word you have come to visit the ideal blog. Our site gives you suggestions for seeing the highest quality video and image content, hunt and find more informative video articles and graphics that fit your interests. comprises one of tens of thousands of movie collections from several sources, especially Youtube, therefore we recommend this movie for you to see. This site is for them to stop by this website.


Honeywell Temp Sensor Rspt 1000 Hvac Controls Humidity Sensor Temperature And Humidity

The smallest frame size consists of CI 6-15 22-75 kW the middle contains the CI 16-30 range 75-15 kW and the largest frame size is represented by the CI 32-50 15-25 kW.

Danfoss type ci 16 wiring diagram. The Danfoss thermal overload relays TI 16C-30C cover the range from 013-32 Amp and protect squirrel cage motors of up to 15 kW against overload. To 4 kW and control relays contactors from 22 to 238 kW. The Danfoss mini contactor CI 4-5 Now replaced by CI 5 was a small compact unit typically with 3 NO main contacts and a built-in normally open NO or normally closed NC auxiliary contact.

The lefthand pressure bellows control the pump pressure. Dave Without knowing the switch type it is hard to be 100 sure but I think you have a 3-pole switch 1 to 2 3 to 4 5 to 6. AC-3 power 220-240 V.

The team have specialist Danfoss knowledge and training to assist our customers with their enquiries. V AC A kW HP TCI 25C 220 240 25 40 55 037N0086 Technical Data Output specifications Operational voltage 220 240 V AC Operational current AC-3 AC-53a 25 A max. Danfoss Fp715si Programmer Wiring Diagram.

The compressors are intended especially for use in mobile applications eg. This diagram shows the wiring layout using the most typical. For use with contactors CI 6 - CI 30.

AC-3 power 220-240 V. Danfoss controls including transmitters solenoid valves pressure and temperature switches. KPU 16 Pressure Switch SPDT with LPHP signal.

Supply is L-1 N-5. 50 mA min Semiconductor protection fusing Type 1 co-ordination. AC-1 load Ith open.

Coil voltage 50 Hz Max 240 V. The system components must not contain any chlorine mineral oil or other oily substances. Is the least efficient diagram among the electrical wiring diagram.

This is particularly important for delta connected motors. CI 110-180 Contactor - Download CI 5 Mini contactor - Download CI 6-50 Contactor. However a parking terminal is provided on the wallplate which is clearly marked with an Earth symbol.

Electrical ratings according to ULDanfoss dual pressure switch type KP 44 is designed for use as a pump guard to control and protect supply water pumps. Use only dry components and avoid moisture entering the system. All frame sizes are provided with three NO main contacts.

MBC 5000 Block-type compact pressure switches. Prior to mounting the plug-on module DIL switches on the rear of the plug-on module must be set. Forgot to mark wires to original post diagram.

DC 6 4 10 6 12 8 16 10 CI 16202530 10 6 16 10 22 15 30 20 CI 25 EICI 30 EI 10 6 16 10 22 15 30 20 CI 25 DCCI 30 DC. Mains contactor4 Danfoss type CI 6 CI 12 CI 9 CI 16 CI 32 CI 32 CI37 CI 85 CI 85 CI 85 AC value AC-3 AC-3 AC-1 AC-1 AC-1 AC-1 AC-1 AC-1 AC-1 AC-1 Supply voltage VDE 0160 V 3 x 200220230 10 3 x 220230240 V. AC-1 load Ithe enclosure.

Motor Power Code no. The smallest frame size consists of CI 6-15 22-75 kW the middle contains the CI 16-30 range 75-15 kW and the largest frame size is represented by the CI 32-50 15-25 kW. Danfoss Pressure Transmitter Wiring Diagram 19112018 19112018 7 Comments on Danfoss Pressure Transmitter Wiring Diagram The standard pressure transmitters MBS 32 and MBS 33 are designed for use in almost all industrial applications and offer reliable pressure measurements.

Ambient temperature 40C Installation. The valve body 3 on the compressor Oil injection control assembly Attach the connector 4 to the coil using the delivered accessories 5 and 6. Refrigeration and air conditioning.

CI 9 EI230. The Danfoss CI9 misread as C19 contactor is part of the contactor programme CI 6-50 which is based on three frame sizes. The phase failure function accelerates the trip function by three phase run if a phase drop-out occurs.

CE EAC LLC CDC TYSK UL CMIM. 188 forum posts 1 photos. FP715 models are double insulated and do not require an earth connection.

Danfoss contactors CI range CI4 CI5 CI6 CI9 CI12 CI15 CI16 CI20 CI25 CI30 and CI61 up to CIEI420 which includes mini contactors from 22. It combines the functions of a pressure switch and a flow monitoring device. Motor is L-2 N-6.

AC-3 power 380-690 V. If you are looking for Danfoss USA Product Store and catalog - which enables you to purchase our products - then please select the USA Product Store button. Danfoss variable speed refrigeration compressors type BD35F BD50F and BD80F are designed for connection to 12V and 24V DC power supply and for refrigerant R134a CF 3-CH 2 F.

If mains contactors are used the following Danfoss types are recommended. 79 forum posts 9 photos. 100 A gLgG Type 2 co-ordination.

AC-3 power 380-690 V. For wiring connections refer to Diagram 1 below. Maximum test pressure must not exceed 32 bar.

The smallest frame size consists of CI 6-15 22-75 kW the middle contains the CI 16-30 range 75-15 kW and the largest frame size is represented by the CI 32-50 15-25 kW. CI 6-15 are available with four NO main contacts. The contactor programme CI 6-50 is based on three frame sizes.

MBC 5080 Block-type differential pressure switches. Coil voltage 50 Hz Min 220 V. 4 Refrigerant charging Refrigerant charging N0 N1 N2 T0 T1 T2 A00 A01 and A04 Fig.

Type Line Voltage Motor Current max.