1200 W Pilot Duty Rating. Humidity range 5 to 95 percent noncondensing wire size 16 motor horsepower 12.

Rib21cdc Wiring Diagram - If you're searching for video and picture information linked to the keyword you've come to pay a visit to the ideal site. Our site provides you with suggestions for viewing the maximum quality video and image content, search and find more informative video articles and images that fit your interests. includes one of thousands of movie collections from several sources, particularly Youtube, so we recommend this video for you to see. This site is for them to stop by this site.


Dry Contact Input Relays

RIB01 RIB02 23 H x 32 W x 18 D.

Rib21cdc wiring diagram. Welcome to the Relay in a Box product series. Relay and Current Sensor in One. Additional Fees may apply for cutting services or pulling heads.

In this single phase home supply wiring diagram the main supply single phase live red wire and the neutral black wire transformer 3 phase 4 wire system come from the secondary to the single phase energy meter note that the single phase The supply is 230 V AC and 120 V AC in the US These two lines of two meter line and neutral are. If more than one dry contact RIB shares a single dry contact input WhiteBlue must be common. Today we will be looking at the RIB21CDC which is a dry contact input relay.

Functional Devices RIB21CDC NECC offers Enclosed Pilot Relay 10a Spdt. Housing TypeNEMA 1 plemum. RIB21CDC Enclosed Relay 10 Amp SPDT Class 2 Dry Contact Input 120-277 Vac Power Input RIB21CDC-RD Red housing RIB21CDC-N4 NEMA 4X housing UL508 only SPECIFICATIONS DRY CONTACT INPUT RELAY.

SMARTENGINE SOLUTION SINGLE-LINE DIAGRAM RIB RELAY RIB21CDC AC LINE VOLTAGE WHITE BLUE WHITE RED 120-277 VAC NEUTRAL OR OTHER PHASE BLACK CONTROL CIRCUIT ORANGE NO YELLOW NC BLUE AC FIXTURE 120-240VAC autoranging WHITE or RED Please see specific wiring diagram available septerately. If thats the case you may not need the second switch. Directly startstop load and current sensing all in one package no external ring is needed Wire colors to Load and 60 Hz ac differ depending on the model being used.

RIB21CDC Enclosed Relay 10 Amp SPDT Class 2 Dry Contact Input 120-277 Vac Power Input RIB21CDC-RD Red housing RIB21CDC-N4 NEMA 4X housing UL508 only Specifications Dry Contact Relays. First choose the wire then the reel number where you want it spooled. Usually one door has to be open before the other can be opened.

RIB21CDC would be just the thing. SMARTENGINE READY 1-CHANNEL FIXTURES. Does not require a transformer to power the relay.

ADI FY-RIB21CDCR Model. 20 A Power Supply. Manufacturers part number rib21cdc.

Safe low voltage Class II wiring can be run to a dry contact switch on the door or any place desired. 58 x 81 x 46 cm RIB21CDC 17 H x 28 W x 15 D 43 x 71 x 38 cm ApprovalUL File E68805. Close WhiteRed wire to WhiteBlue wire to activate relay.

RIB21CDC-RD Name DRY CNTCT INPUT RELAY 10A-RED. 5 Pin Power Relay Diagram Wiring Schematic -Mercruiser Ignition Switch Wiring Diagram Begeboy Wiring Diagram Source 5 pin relay wiring diagram door lock diagram data schema exp RIB21CDC Enclosed Relay 10 Amp SPDT Class 2 Dry Contact Input 120-277 - HVAC Surplus. Line Voltage Fixtures120V-277V 10ARIBRELAY RIB21CDC Plug Load Monitoring120V-277V 10A 120V 20A 277V 20A RIBRELAY RIB21CDC RIBRELAY RIB01BDC RIBRELAY RIB02BDC 120-240VAC autoranging WHITE or RED Please see specific wiring diagram available septerately.

Configurations are either YELLOW ORANGE BLUE YELLOW or ORANGE ORANGE. Wire Length16 406 cm Operating Temperature-30 to 140F -344 to 60F Operating Humidity5 to 95 non-condensing. Functional Devices Rib21cdc-Rd Relay.

Closet Light RIB21CDC Light Fixture Junction Box Class II Wiring Dry-Contact Door Switch Closet Door 120 Vac Power Class II Wiring Blue Not Used BLACK YELLOW RED ORANGE Line Neutral RIB21CDC Light Fixture. Class 2 Horse Power. Functional Devices RIBU1C - Enclosed Pilot Relay 10 Amp SPDT w 10-30 VacDC120 Vac Coil - Enclosed Pilot Relay 10 Amp SPDT w 10-30 VacDC120 Vac Coil.

Wire Length 16 406 cm Operating Temperature -30 to 140F -344 to 60F Operating Humidity 5 to 95 non-condensing Housing Type NEMA 1 plemum Conduit Hub 12 NPT Dimensions RIB01 RIB02 23 H x 32 W x 18 D 58 x 81 x 46 cm RIB21CDC 17 H x 28 W x 15 D 43 x 71 x 38 cm Approval UL File E68805 Warranty 1 year DESCRIPTION. Pilot duty 470 va relays 1. SMARTENGINE READY 1-CHANNEL FIXTURES RJ45 PATCH CORDS SE-SI-2CH SE-SI-1CH.

22 gauge low voltage cable between the door contact and RIB. Close WhiteRed wire to WhiteBlue wire to activate relay. In this setup you can see the devi.

If more than one dry contact RIB shares a single dry contact input WhiteBlue must be common. Close WhiteRed wire to WhiteBlue wire to activate relay. If more than one DRY-CONTACT RIB shares a single dry-contact input WhiteBlue must be common.

Item Notes Optional Note. RIB21CDC Enclosed Relay 10 Amp SPDT Class 2 Dry Contact Input 120-277 Vac Power Input RIB21CDC-RD Red housing RIB21CDC-N4 NEMA 4X housing UL508 only Made in USA Meets Buy American.


Ribd01bdc Ribd02bdc Manualzz


Rib21cdc Enclosed Relay 10 Amp Spdt Class 2 Dry Contact Input 120 277 Hvac Surplus


Wiring Diagram For Dry Contact Relay


Functional Devices Relay In A Box Series Rib21cdc Dry Contact Youtube


Details Functional Devices Inc


Using Rib Relays To Control Bathroom Fans Lights Functional Devices Inc


Rib21cdc Enclosed Relay 10 Amp Spdt Class 2 Dry Contact Input 120 277 Hvac Surplus


Wiring Diagram For Dry Contact Relay


Rib21cdc Enclosed Relay 10 Amp Spdt Class 2 Dry Contact Input 120 277 Hvac Surplus


Related Posts